Battery Electrical Drain/ Parasitic Load Test Repair Manual

download
1. Disconnect the battery negative cable 2. Install the male end of the J 38758 to the negative battery terminal. 3. Turn OFF the test switch. 4. Install the negative battery cable to the female end of the test switch. 5. Install the Scan Tool (or equivalent) or wait for 20 minutes. 6. Turn ON the test switch. 7. Road test the vehicle while activating all accessories, including the radio and the air conditioning. 8. Lower the door glass, then exit the vehicle. Do not move the door handle after closing the door. 9. Open the hood. Important The power down timer will reset to 20 minutes if any wake up inputs are received by a Class 2 device (after the scan tool has put all Class 2 devices to sleep). 10. Put all of the Class 2 devices into the sleep mode. 11. Turn OFF the ignition switch. Remove the key. Important From this point on, electrical continuity must be maintained in the ground circuit of the battery through the Test Switch J 38758 in the ON position or through the ammeter J 39200 . 12. Components such as PCM, VCM, Automatic Air Conditioning, and the Truck Body Control Module have timers that draw several amps of current while they cycle down. This can give a false parasitic drain reading. Wait 20 minutes for these components to power down before continuing this test (or use the scan tool to put all Class 2 devices to sleep). 13. Connect a jumper wire with a 10 A fuse J 36169-A to the terminals of the test switch. 14. Turn the test switch to the OFF position. 15. Wait ten seconds. If the fuse does not blow, the current is less than 10 A. The ammeter can be used safely. 16. Before the fused jumper wire is removed, turn the test switch to the ON position. Important If an ammeter other than the J 39200 is used, ensure that the vehicle does not have a high current drain that would damage the ammeter when connected to the circuit. 17. Perform the following procedure in order to detect a high current drain: A. Set the ammeter J 39200 to the 10 A scale. B. Connect the ammeter to the test switch terminals. C. Turn OFF the test switch. This allows the current to flow through the ammeter. D. Wait one minute, then inspect the current reading. Ñ When there is a current reading of 2 A or less, turn ON the test switch, this maintains continuity in the electrical system. Ñ Then, switch the meter down to the 2 A scale, for a more accurate reading, when the test switch is reopened. E. Open the test switch. F. Take the reading in milliamps. G. Note the battery reserve capacity. Refer to Battery Usage . Ñ Divide this number by 4. Example: 90/4 = 22.5 Ñ Compare this to the ammeter reading. Ñ The current drain in milliamps should not exceed this number. Ñ Example: if a battery has a reserve capacity of 90 minutes, the current drain should not exceed 22 milliamps. H. When the current draw is too high, remove the electrical system fuses one at a time until the draw returns to a value less than or equal to specifications. Ñ Start with the fuses that are hot all the time. Ñ To remove the fuse, you must first open the door, which causes a high enough current flow to damage the ammeter. Ñ Protect the ammeter, without disturbing the electrical continuity, by turning ON the test tool before opening the door. Ñ Remove the courtesy lamp fuse. Ñ Note the ammeter reading. Ñ If the parasitic load is still excessive, start removing the remaining fuses one at a time. Ñ Keep the courtesy lamp fuse out during diagnosis, so the door can remain open. Ñ Perform Steps 11 through 13 each time a fuse is removed. I. Removing the PCM or VCM fuse should cause a drop of less than 10 milliamps. A drop greater than 10 milliamps indicates a possible short to ground. J. Check the orange wires along with the components connected to the orange wires. No drop in the milliampere reading indicates the PCM or VCM is not drawing current. K. Repeat the parasitic current drain test procedure after any repair has been completed. L. When the cause of the excessive current draw has been located and repaired, remove the ammeter and the parasitic draw test switch.

2001 Ford F-150 Draining-Coalescer/ Pressure Relief-Natural Gas Bi-Fuel System Repair Manual

download
1. Relieve the Bi-fuel system fuel pressure. For additional information, refer to Pressure Relief—Natural Gas Bi-Fuel System. 2. Raise the vehicle on the hoist. For additional information, refer to Section 100-02. 3. NOTE: There is an O-ring attached to the drain plug. The O-ring must be replaced each time the drain plug is removed. Remove the drain plug. 4. Install the drain plug. 5. Lower the vehicle. 6. Pressurize the fuel system. WARNING: It is important that your bi-fuel vehicle be correctly maintained by Ford bi-fuel trained personnel. If a concern occurs, it is important that correctly trained personnel diagnose the cause. If a concern relates to the fuel system, correct part replacement is imperative to keep your vehicle operating at normal performance. Bi-fuel components and gasoline specific components are not interchangeable. If your vehicle is not serviced in accordance with bi-fuel service procedures, damage can occur and your warranty may be invalidated. WARNING: Fuel supply lines are always pressurized. When servicing fuel related components, do not smoke or carry lighted tobacco or an open flame of any type. Flammable mixtures may be present and can ignite, resulting in personal injury. WARNING: The natural gas fuel system is always pressurized to 655 kPa (95 psi) downstream of the fuel pressure regulator and up to 24821 kPa (3,600 psi) upstream of the fuel pressure regulator. Use care when servicing the fuel system or personal injury can occur. WARNING: The natural gas fuel supply manifold is pressurized to 655 kPa (95 psi). Fuel pressure must be relieved prior to any fuel system service. WARNING: The fuel system pressure must be relieved before any component can be removed. The fuel tanks must be evacuated prior to tank removal. Removal of components without pressure relief or tank evacuation can cause natural gas to escape into the air and cause injury or death.

Battery Electrical Drain/ Parasitic Load Test

download
1. Disconnect the battery negative cable. 2. Install the male end of the J 38758 to the negative battery terminal. 3. Turn OFF the test switch. 4. Install the negative battery cable to the female end of the test switch. 5. Install the Scan Tool (or equivalent) or wait for 20 minutes. 6. Turn ON the test switch. 7. Road test the vehicle while activating all accessories, including the radio and the air conditioning. 8. Lower the door glass, then exit the vehicle. Do not move the door handle after closing the door. 9. Open the hood. Important The power down timer will reset to 20 minutes if any wake up inputs are received by a Class 2 device (after the scan tool has put all Class 2 devices to sleep). 10. Put all of the Class 2 devices into the sleep mode. 11. Turn OFF the ignition switch. Remove the key. Important From this point on, electrical continuity must be maintained in the ground circuit of the battery through the Test Switch J 38758 in the ON position or through the ammeter J 39200 . 12. Components such as PCM, VCM, Automatic Air Conditioning, and the Truck Body Control Module have timers that draw several amps of current while they cycle down. This can give a false parasitic drain reading. Wait 20 minutes for these components to power down before continuing this test (or use the scan tool to put all Class 2 devices to sleep). 13. Connect a jumper wire with a 10 A fuse J 36169-A to the terminals of the test switch. 14. Turn the test switch to the OFF position. 15. Wait ten seconds. If the fuse does not blow, the current is less than 10 A. The ammeter can be used safely. 16. Before the fused jumper wire is removed, turn the test switch to the ON position. Important

2006 Ford Five Hundred SE UPPER INTAKE MANIFOLD REMOVAL AND INSTALLATION MANUAL

download
Removal All vehicles 1. Drain the cooling system. For additional information, refer to DRAINING . 2. Disconnect the battery ground cable. For additional information, refer to REMOVAL AND INSTALLATION . 3. Remove the air cleaner outlet pipe. For additional information, refer to REMOVAL AND INSTALLATION . 4. Remove the 4 transaxle roll restrictor cross brace bolts 5. Remove the bolt and the transaxle roll restrictor cross brace. 6. Disconnect the evaporative emissions (EVAP) canister purge valve tube from the upper intake manifold and detach the retainer. 7. Disconnect the positive crankcase ventilation (PCV), brake booster and vacuum harness tubes from the upper intake manifold. 8. Detach the fuel tube retainer from the upper intake manifold. 9. Disconnect the exhaust gas recirculation (EGR) system module electrical connector and vacuum tube. 10. Detach the vacuum tube from the upper intake manifold vacuum tube retainer. 11. Disconnect the EGR system module tube from the EGR system module. Early build 12. Disconnect and plug the throttle body and PCV coolant hoses. Late build 13. Disconnect and plug the 2 PCV coolant hoses. All vehicles 14. Disconnect the throttle body electrical connector. 15. If equipped, remove and discard the 4 upper-to-lower intake manifold screws. 16. Remove the 8 bolts and the upper intake manifold. * Remove and discard the gaskets. Installation All vehicles Fig. 4: Identifying Tightening Sequence Of Bolts Courtesy of FORD MOTOR CO. NOTE: Clean and inspect all sealing surfaces. Install new gaskets 1. Position the upper intake manifold and install the 8 bolts. * Tighten in the sequence shown to 10 N.m (89 lb-in). 2. Connect the throttle body electrical connector. Late build 3. Connect the 2 PCV coolant hoses. Early build 4. Connect the throttle body and PCV coolant hoses. All vehicle 5. Connect the EGR system module tube to the EGR system module. * Tighten to 40 N.m (30 lb-ft). 6. Attach the vacuum tube to the upper intake manifold vacuum tube retainer. 7. Connect the EGR system module electrical connector and vacuum tube. 8. Attach the fuel tube retainer to the upper intake manifold. 9. Connect the PCV, brake booster and vacuum harness tubes to the upper intake manifold. 10. Connect the EVAP canister purge valve tube to the upper intake manifold and attach the retainer. 11. Clean the 4 transaxle roll restrictor cross brace bolts using a wire brush and apply new threadlock to the threads. 12. Position the transaxle roll restrictor cross brace and install the 4 new bolts. * Tighten to 55 N.m (41 lb-ft). 13. Clean the transaxle roll restrictor cross brace-to-roll restrictor bolt using a wire brush and apply new threadlock to the threads. 14. Install a new transaxle roll restrictor cross brace-to-roll restrictor bolt. * Tighten to 48 N.m (35 lb-ft). 15. Install the air cleaner outlet pipe. For additional information, refer to REMOVAL AND INSTALLATION . 16. Connect the battery ground cable. For additional information, refer to REMOVAL AND INSTALLATION . 17. Fill and bleed the cooling system.

2001 Ford Taurus/ Sable Cooling System Draining Filling and Bleeding Workshop Manual

download
CAUTION: Vehicle cooling systems are filled with Motorcraft Premium Engine Coolant VC-4-A (in Oregon VC-5, in Canada CXC-10) or an equivalent meeting Ford specification ESE-M97B44-A. NOTE: Less than 80% of the coolant capacity can be recovered with the engine in the vehicle. Dirty, rusty or contaminated coolant requires replacement. 1. Release the pressure in the cooling system by slowly turning the pressure relief cap one half to one turn counterclockwise to the first stop on the filler neck. When the pressure has been released, remove the pressure relief cap. 2. Raise and support the vehicle. For additional information, refer to Section 100-02 . 3. Remove the front splash shield. 4. Place a suitable container below the radiator draincock. Drain the coolant. 5. Close the radiator draincock when finished. Filling and Bleeding With RADKITPLUS 1. Using the special tool, install the RADKITPLUS and follow the RADKITPLUS manufacturer’s instructions to fill and bleed the cooling system. Filling Without RADKITPLUS CAUTION: Engine coolant provides freeze protection, boil protection, cooling efficiency and corrosion protection to the engine and cooling components. In order to obtain these protections, the engine coolant must be maintained at the correct concentration and fluid level. When adding engine coolant, use a 50/50 mixture of engine coolant and clean, drinkable water. To maintain the integrity of the coolant and the cooling system: * Add Motorcraft Premium Engine Coolant VC-4-A (in Oregon VC-5, in Canada CXC-10) or equivalent meeting Ford specification ESE-M97B44-A. * Do not add Motorcraft Specialty Engine Coolant VC-2 or an equivalent meeting Ford specification WSS-M97B44-D. Mixing coolants may degrade the coolant’s corrosion protection. * Do not add alcohol, methanol, brine or any engine coolants mixed with alcohol or methanol antifreeze. These can cause engine damage from overheating or freezing. * Do not mix with recycled coolant unless it meets the requirement of specification ESE-M97B44-A. Not all coolant recycling processes meet this specification. Use of such a coolant may harm the engine and cooling system components. 1. Install the front splash shield. 2. Lower the vehicle. 3. Fill the degas bottle with the correct engine coolant mixture. 4. Install the pressure relief cap. 5. Move the temperature blend selector to the full warm position. 6. WARNING: Do not stand in line with or near the engine cooling fan blade when revving the engine. Run the engine until it reaches operating temperature. 7. Add the correct coolant mixture to the degas bottle until the coolant level is between the COOLANT FILL LEVEL marks. 8. Turn off the engine and allow the cooling system to cool. Recheck the coolant level and fill the cooling system to the FULL mark on the degas bottle. 9. WARNING: Do not stand in line with or near the engine cooling fan blade when revving the engine. Repeat Steps 3 through 8 until the reservoir level is OK. Bleeding Without RADKITPLUS 1. Bleed the cooling system as follows: * Select the maximum heater temperature and blower motor speed settings. Position the control to discharge air from the A/C vents in the instrument panel. * WARNING: Do not stand in line with or near the engine cooling fan blade when revving the engine. Start the engine and allow it to idle. While the engine is idling, feel for hot air from the A/C vents. * CAUTION: If the air discharge remains cool and the engine coolant temperature gauge does not move, the engine coolant level is low in the engine and must be filled. Stop the engine, allow it to cool and fill the cooling system. Start the engine and allow it to idle until the normal operating temperature is reached. Hot air should discharge from the A/C vents. The engine coolant temperature gauge should maintain a stabilized reading in the middle of the NORMAL range and the upper radiator hose should feel hot to the touch. * Shut the engine off and allow it to cool. * Check the engine for coolant leaks. * Check the engine coolant level in the degas bottle and fill it as necessary.