Skip to content

2003 dodge ram 3500 relay blower motor located

You search PDF repair manual about 2003 dodge ram 3500 relay blower motor located, if there are search results will appear below. If search results do not exist, please search by others keyword.

2001 Dodge Durango BLOWER MOTOR RELAYS REPAIR MANUAL

download
BLOWER MOTOR RESISTOR 1. Disconnect negative battery cable. Disconnect blower motor resistor harness connector. Using DVOM, check for continuity between all blower motor resistor terminals. If continuity exists between all terminals, go to next step. If continuity does not exist between all terminals, replace faulty blower motor resistor. 2. Check for open or short in circuits between blower motor resistor and heater control panel. Also check for open or short in wire between blower motor resistor and blower motor. BLOWER MOTOR SWITCH 2000 Dakota, 2000 Durango & 2000-01 Ram Pickup 1. Remove Power Distribution Center (PDC) cover. Using DVOM, check for battery voltage at PDC fuse No. 5 (40-amp) on Dakota and Durango; PDC fuse No. 12 (40-amp) on Ram Pickup. If battery voltage exists, go to next step. If battery voltage does not exist, check for open in Red wire between battery and underhood PDC. If Red wire is okay, replace underhood PDC. 2. Disconnect negative battery cable. Remove heater control panel. See HEATER CONTROL PANEL under REMOVAL & INSTALLATION. Disconnect heater control panel cable, electrical and vacuum connectors as necessary. Using DVOM, check for continuity between heater control panel harness connector terminal No. 7 (Black wire on Dakota and Durango; Black/Orange on Ram Pickup) and ground. See Fig. 5 . If continuity exists, go to step 4 . 3. If continuity does not exist, repair open in Black wire or Black/Orange wire between heater control panel 2001 Dodge Durango 2000-01 HEATER SYSTEMS’ ‘RWD Trucks & Vans harness connector terminal No. 7 and ground connector located at lower right corner of instrument panel (Dakota and Durango) or behind center of instrument panel (Ram Pickup). 4. Place heater mode control knob to any position except OFF. Using DVOM, check for continuity between heater control panel terminal No. 7 and terminals No. 3, 4, 5 and 6 while rotating blower motor switch. See Fig. 5 . 5. If continuity does not exist at any terminal, replace faulty heater control panel. If continuity exists as specified, check for open in circuits between heater control panel and blower motor resistor. Also check for an open in circuit between heater control panel and blower motor. See WIRING DIAGRAMS . Fig. 5: Identifying Heater Control Panel Blower Switch Connector Terminals (2000 Dakota & Durango Are Shown; Ram Pickup Is Similar) Courtesy of CHRYSLER CORP. Ram Van/Wagon 1. Disconnect negative battery cable. Remove heater control panel. See HEATER CONTROL PANEL under REMOVAL & INSTALLATION. Disconnect heater control panel harness connectors. Using DVOM, check for continuity between heater control panel C3 harness connector terminal “C” (Black wire) and ground. See Fig. 6 . If continuity exists, go to next step. If continuity does not exist, repair open in Black wire between heater control panel and ground connector located at lower right of steering column. 2. Place heater mode control selector to any position, except OFF. Using DVOM, check for continuity between appropriate terminals of heater control panel, for C3 connector terminals “B” (Violet wire) and “C” (Black wire). If continuity exists through heater control panel, go to next step. If continuity does not exist, replace faulty heater control panel assembly. 3. Using DVOM, check for continuity between heater control panel C3 connector terminal “B” (Violet wire) and C1 connector terminal “E” (Violet wire). See Fig. 6 . If continuity exists, go to next step. If continuity does not exist, repair open in Violet wire between heater control panel C3 and C1 connectors.

2001-2004 FORD Taurus WATER IN THE BLOWER CASE—BLOWER MOTOR SERVICE PROCEDURE

download
SERVICE PROCEDURE 1. Access blower motor and resistor per the Workshop Manual Sections 412-02 and 412-04. Inspect for evidence of water/corrosion. If water/corrosion are found or parts have failed, replace per Workshop Manual (blower motor 1F1Z-19805-AA and resistor F6DZ-19A706-AA). 2. Visually inspect the Cowl Vent Screen located under the RH windshield wiper to verify if the Figure 1 – Article 04-15-3 screen is fully seated. Inspect the rubber seal on the vent screen which should be fully seated 5. Locate the tape as shown (Figure 2). Remove against the windshield. If the cowl vent screen the tape and apply Clear Silicone Rubber is not fully seated and appears warped, it must TA-32 to the small hole as shown (Figure 2). be replaced (4F1Z-54018A16-BAA) 3. Remove the cowl vent screen per the vehicle model years and build date information. Workshop Manual Section 412-01 Pollen Filter Removal and inspect the cabin filter to confirm ISSUE it is fully seated. Re-seat the filter as Some vehicles built between 5/1/2001 and necessary. Inspect rain-hat base to make sure 12/15/2003 may exhibit water in the blower case or it is secure and sealed to the body. Reposition on the passenger side floor, an inoperative climate and reseal as necessary using Clear Silicone control blower motor, a motor that operates on high Rubber TA-32. speed only, and/or a blower motor resistor failure. 4. Remove the foam sealant expulsion at lower front outboard corner base of the rain-hat ACTION (Figure 1). Inspect and seal cowl area and install Rain-Hat Extension Seal. Inspect and replace blower motor and/or blower motor resistor if there is evidence of water/corrosion. Refer to the following Service Procedure for details.

2002 Ford Taurus WATER IN THE BLOWER CASE BLOWER MOTOR AND/ OR RESISTOR FAILURE REPAIR MANUAL

download
SERVICE PROCEDURE 1. Access blower motor and resistor per the Workshop Manual Sections 412-02 and 412-04. Inspect for evidence of water/corrosion. If water/corrosion are found or parts have failed, replace per Workshop Manual (blower motor 1F1Z- 19805-AA and resistor F6DZ-19A706-AA). 2. Visually inspect the Cowl Vent Screen located under the RH windshield wiper to verify if the screen is fully seated. Inspect the rubber seal on the vent screen which should be fully seated against the windshield. If the cowl vent screen is not fully seated and appears warped, it must be replaced (4F1Z-54018A16- BAA). 3. Remove the cowl vent screen per the Workshop Manual Section 412-01 Pollen Filter Removal and inspect the cabin filter to confirm it is fully seated. Re-seat the filter as necessary. Inspect rain-hat base to make sure it is secure and sealed to the body. Reposition and reseal as necessary using Clear Silicone Rubber TA-32. 4. Remove the foam sealant expulsion at lower front outboard corner base of the rain-hat (Figure 1). Zoom Sized for Print 5. Locate the tape as shown (Figure 2). Remove the tape and apply Clear Silicone Rubber TA-32 to the small hole as shown (Figure 2) Parts Block Zoom Sized for Print 6. Install the Rain-Hat Extension Seal or Shed Lip Seal 4F1Z-54022A54-AA to the outboard edge of the rain-hat (see Figure 2 for installation). The 10 mm by 10 mm (0.5″ by 0.5″) cut area, located 25 mm (1″) from the end of the seal, will face down and locate at the 90 degree bend of the rain-hat on the fender side (Figure 3). 7. Prior to installation of the cowl vent screen, verify that the cabin filter cover is properly snapped in place and the clip is located on the inboard side, (toward the center of the bulkhead), the cover will feel loose if not properly snapped in place. Reinstall the cowl vent screen per Section 412-01 of the Workshop Manual.

2005 Chevy Truck Silverado 1500 2WD Blower Motor Resistor Replacement

download
Blower Motor Resistor Replacement Notes BLOWER MOTOR RESISTOR REPLACEMENT REMOVAL PROCEDURE 1. If equipped, remove the IP sound insulator. 2. Disconnect the electrical connection from the blower motor . 3. Disconnect the electrical connection from the blower motor resistor 4. Remove the blower motor resistor retaining screws. 5. Remove the blower motor resistor. INSTALLATION PROCEDURE 1. Install the blower motor resistor. NOTE: Refer to Fastener Notice in Service Precautions. 2. Install the blower motor resistor retaining screws. Tighten Tighten the screws to 1.6 N.m (14 lb in) . 3. Connect the electrical connection to the blower motor resistor. 4. Connect the electrical connection to the blower motor . 5. If equipped, install the IP sound insulator.

1991 Honda Civic Si FUSES AND CIRCUIT BREAKERS Identification

download
IDENTIFICATION FUSE PANEL LOCATION The fuse box is located under dashboard on driver’s side. Underhood fuse panel is located in engine compartment beside battery. Cars equipped with anti-lock brake system have a third fuse box for ABS in front of the engine compartment on passenger’s side. FUSE PANEL IDENTIFICATION (1988-91) Fig. 1: Fuse Panel Identification (1988-91) Courtesy of AMERICAN HONDA MOTOR CO., INC. Fuse & Circuit Breaker Identification z 1 – 10 Amp Integrated Control Unit, Combination Switch, Gauge Assembly, Back-Up Lights Switch, Shift Position Console Switch, Clock (1990) , Shift Lock Solenoid (1990) , Interlock Control Unit (1990) , 1991 Honda Civic Si FUSES & CIRCUIT BREAKERS’ ‘Fuses & Circuit Breakers 1988-91 Honda 1991 Honda Civic Si FUSES & CIRCUIT BREAKERS’ ‘Fuses & Circuit Breakers 1988-91 Automatic Seat Belts (If Equipped) z 2 – 10 Amp Starter Solenoid, PGM-FI Main Relay, PGM-FI Electronic Control Unit, Integrated Control Unit z 3 – 20 Amp Power Door Locks (If Equipped) z 4 – 10 Amp Right Headlight High Beam, High Beam Indicator Light, Daytime Running Lights Relay (Canada) z 5 – 10 Amp Left Headlight High Beam z 6 – 30 Amp Sun Roof Motor (If Equipped) z 7 – 10 Amp Rear Lights (Canada Only) z 8 – 10 Amp Integrated Control Unit, Interior & Exterior Lighting z 9 – Blank z 10 – 10 Amp Left Headlight Low Beam z 11 – 10 Amp Right Headlight Low Beam z 12 – 15 Amp Integrated Control Unit, Luggage Compartment Light, Dome Light, Ignition Switch, Clock, Radio, Cigarette Lighter z 13 – 15/20 Amp Power Windows, Windshield Wipers & Washer, Sun Roof Relay (1990), Integrated Control Unit (Canada), Combination Switch (1990 CRX) z 14 – 10 Amp Gauge Assembly, Engine Sensors & Controls, PGM-FI Main Relay (Wagon & CRX Only), PGM-FI ECU (Wagon & CRX Only), Fuel Pump (Wagon & CRX Only), ELD Unit (Wagon & CRX Only), EACV (Wagon & CRX Only) z 15 – 15 Amp Cooling Fan Motor (Except 4WD A/T Wagon), Cooling Fan Relay z 16 – 10 Amp Daytime Running Lights (Canada Only) z 17 – 10 Amp Radio, Cigarette Lighter Relay (1990 only) z 18 – 10 Amp Rear Window Defogger, Power Door Mirrors, Air Conditioning z 19 – 30 Amp Blower Motor z 20 – 20 Amp Right Front Power Window z 21 – 20 Amp Left Front Power Window z 22 – 20 Amp Right Rear Power Window z 23 – 20 Amp Left Rear Power Window UNDERHOOD FUSE PANEL IDENTIFICATION (1988-91)