Skip to content

2007 ford e250 fuel gauge

You search PDF repair manual about 2007 ford e250 fuel gauge, if there are search results will appear below. If search results do not exist, please search by others keyword.

2004-2007 Ford Explorer MIL ON WITH DTC P0463 OR ERRATIC FUEL GAUGE OPERATION SERVICE PROCEDURE

download
ACTION Follow the Service Procedure steps to correct the condition. SERVICE PROCEDURE 1. For vehicles with customer symptom of erratic fuel gauge operation (with no MIL on), proceed to Step 1a. For vehicles with a customer symptom including the MIL on, proceed to Step 1b. If unable to verify the concern, do not continue with this TSB. a. Follow the appropriate pinpoint test (PPT) for “Fuel Gauge Inaccurate” in Workshop Manual (WSM), Section 413-01. If PPT test results lead to fuel pump module replacement, proceed to Step 2. If PPT test results isolate any problem other than fuel pump module replacement, repair as indicated and do not continue with this TSB. b. Install diagnostic scan tool to retrieve DTCs. If DTC P0463 is retrieved, proceed to Step 2. If DTC P0463 is not retrieved, this TSB does not apply, follow normal WSM diagnostics. 2. Remove fuel tank per WSM, Section 310-01 3. Remove fuel pump assembly from fuel tank per WSM, Section 310-01. See Figure 1 (Chart) to determine if a kit (contains a fuel level sensor assembly, a wire harness and heat shrink tube) or fuel pump assembly is required for repair. For vehicles that can be serviced with a kit go to Step 4. For vehicles that require fuel pump assembly replacement, go to Step 12. 4. Remove the fuel level sensor assembly (sender card/float rod assembly) from the fuel pump assembly per WSM, Section 310-01

2004-2007 FORD E-150, E-250, E-250, E-350 4.6L / 5.4L ENGINE-SLOW FUEL FILL REPAIR MANUAL

download
ISSUE carbon canister inlet. If there is no free flow Some 2004-2007 E-150 – E-350 vehicles equipped past the CVV, the CVV is failed or frozen with a 4.6L or 5.4L engine and mid-ship fuel tank closed. Replace the CVV. may experience a “Slow to Fill” condition. c. If you have free flow through the CVV and the vent hose, the restriction must be at the ACTION Separator Assembly (Dust Box). Check the Use the Service Procedure to check the canister Canister Separator Assembly for damage, vent tube for a spider web or other obstruction dirt, water or ice contamination and replace before replacing the fuel tank. the Separator Assembly. SERVICE PROCEDURE 2. If the fuel tank is still difficult to fill with the 1. Disconnect the evaporative emission (EVAP) carbon canister disconnected, replace the fuel lines where it connects from the fuel tank to the tank assembly. carbon canister assembly inlet. If the tank can be easily filled, the carbon canister and EVAP PART NUMBER PART NAME lines should be investigated for restriction, 5C2Z-9S327-CA Fuel Vapor Vent continue to Step 1a. If the fuel tank is still 6F1Z-9F945-AA Solenoid Canister Vent difficult to fill with the carbon canister XF2Z-9B328-AA Separator Asy Fuel 6C2Z-9002-AA Tank Asy Fuel disconnected, proceed to Step 2. (Figure 1) F75Z-9F945-CA Solenoid Canister Vent WARRANTY STATUS: Eligible Under Provisions Of New Vehicle Limited Warranty Coverage IMPORTANT: Warranty coverage limits/policies are not altered by a TSB. Warranty coverage limits are determined by the identified causal part. OPERATION DESCRIPTION TIME MT071501 Use SLTS Operations If Actual Available; Claim AdditionalTime Diagnosis Or Labor Figure 1 – Article 07-15-1 Performed As Actual Time DEALER CODING a. Spider webs and other debris in the vent CONDITION hose 5C2Z-9S327-CA may restrict the hose. BASIC PART NO. CODE Disconnect and blow out vent hose with 9S327 55 shop air or roll a bearing down the hose to remove the debris.

2000 Ford Windstar INCORRECT FUEL GAUGE INDICATION Workshop Manual

download
The fuel gauge does not change indication unless there has been at least 3 gallons of fuel added or deleted between ignition switch cycle. Use recorded REM and instrument cluster DTCs from the Continuous and On- Demand self-test. ? Are any DTCs recorded? Yes If REM DTC B1201 or IC DTC U1131 is retrieved, GO to D6 . No GO to D2. D2 CARRY OUT THE ICM FUEL GAUGE ACTIVE COMMAND IC Active Command Select the IC FUEL GAUGE CONTROL active command. Trigger FUELLEVEL active command. Toggle and monitor the fuel gauge while adjusting the FUELLEVEL active command to read 50% and 100% Did the fuel gauge needle start at empty (E), move to half at 50%, and full (F) at 100%? Yes GO to D3. No INSTALL a new instrument cluster; REFER to Instrument Cluster. CLEAR the DTC. REPEAT the instrument cluster self-test. D3 CHECK THE FUEL GAUGE READING Fuel Pump Module C412 Connect one lead of Instrument Gauge System Tester to fuel pump module C412 Pin 5, Circuit 1357 (LB/YE), harness side. Connect the other lead to fuel pump module C412 Pin 8, Circuit 1356 (LG/VT), harness side. Set the power switch on Instrument Gauge System Tester to the ON position Set Instrument Gauge System Tester to 15 ohms. Wait one minute. Set Instrument Gauge System Tester to 160 ohms. Wait one minute. Read the fuel gauge. The fuel gauge should read full or above. Set Instrument Gauge System Tester to 15 ohms. Wait one minute. Read the fuel gauge. The fuel gauge should read empty or below Does the fuel gauge operate correctly? Yes GO to D4. No GO to D6. D4 INSPECT THE FUEL TANK Visually inspect the fuel tank for any damage or deformation. ? Is the fuel tank OK? Yes GO to D5. No INSTALL a new fuel tank. REFER to Section 310-01. TEST the system for normal operation. D5 INSPECT THE FUEL LEVEL SENSOR AND PUMP ASSEMBLY Visually inspect the fuel pump assembly for damaged wiring or connectors. Visually inspect the float and float rod for damage or obstruction

2004-2007 Ford F-Super Duty SLIDING POWER WINDOW (BACK GLASS) SERVICE MANUAL

download
FORD: 2004-2007 F-Super Duty ISSUE SERVICE PROCEDURE Some 2004-2007 F-Super Duty vehicles, equipped with a power sliding rear window (back glass), may 1. Prior to window removal, verify that center exhibit a stuck or binding concern. This condition glass is centered in the upper plastic channel may be due to the center glass not being positioned (Figure 1). If center glass is not inside upper correctly inside the upper or lower channel, the plastic channel, pull channel down and out of channel being warped, bent, or center glass upper aluminum channel and slide back in de-bonded. making sure the entire center glass is inside the plastic channel. ACTION Follow the Service Procedure steps to correct the condition. Figure 1 – Article 06-15-5 2. If Step 1 resolves the issue, return the vehicle 4. Refer to window removal procedure. (Refer to back to customer after verifying the window Workshop Manual (WSM), Section 501-11-24 functions properly. If it did not resolve the and 501-11-25.) issue, proceed to Step 3. 5. Remove cable clips from sheet metal. (Refer to 3. Open the rear window approximately half way. WSM, Section 501-11-28.) 6. Remove three (3) motor bracket attaching bolts. (Refer to WSM, Section 501-11-28. 7. Disconnect motor wiring harness from vehicle 9. Pull outer rubber seal from window frame body harness. (Refer to WSM, Section (Figure 2). 501-11-29.) 8. Remove window assembly from vehicle window opening. Figure 2 – Article 06-15-5 10. Locate two (2) screws in bottom of lower frame and remove them with a R1 square bit screw driver (Figure 3). Figure 3 – Article 06-15-5

2001 Ford F-150 Draining-Coalescer/ Pressure Relief-Natural Gas Bi-Fuel System Repair Manual

download
1. Relieve the Bi-fuel system fuel pressure. For additional information, refer to Pressure Relief—Natural Gas Bi-Fuel System. 2. Raise the vehicle on the hoist. For additional information, refer to Section 100-02. 3. NOTE: There is an O-ring attached to the drain plug. The O-ring must be replaced each time the drain plug is removed. Remove the drain plug. 4. Install the drain plug. 5. Lower the vehicle. 6. Pressurize the fuel system. WARNING: It is important that your bi-fuel vehicle be correctly maintained by Ford bi-fuel trained personnel. If a concern occurs, it is important that correctly trained personnel diagnose the cause. If a concern relates to the fuel system, correct part replacement is imperative to keep your vehicle operating at normal performance. Bi-fuel components and gasoline specific components are not interchangeable. If your vehicle is not serviced in accordance with bi-fuel service procedures, damage can occur and your warranty may be invalidated. WARNING: Fuel supply lines are always pressurized. When servicing fuel related components, do not smoke or carry lighted tobacco or an open flame of any type. Flammable mixtures may be present and can ignite, resulting in personal injury. WARNING: The natural gas fuel system is always pressurized to 655 kPa (95 psi) downstream of the fuel pressure regulator and up to 24821 kPa (3,600 psi) upstream of the fuel pressure regulator. Use care when servicing the fuel system or personal injury can occur. WARNING: The natural gas fuel supply manifold is pressurized to 655 kPa (95 psi). Fuel pressure must be relieved prior to any fuel system service. WARNING: The fuel system pressure must be relieved before any component can be removed. The fuel tanks must be evacuated prior to tank removal. Removal of components without pressure relief or tank evacuation can cause natural gas to escape into the air and cause injury or death.