Skip to content

chilton 2000 mercury sable

You search PDF repair manual about chilton 2000 mercury sable, if there are search results will appear below. If search results do not exist, please search by others keyword.

Ford SVT Contour/ Mercury 2.5L V-6 Cougar (5 Speed Manual Transmission Only) Supercharger System Installation Manual

download
1998-2000 FORD SVT CONTOUR/ MERCURY 2.5L V-6 COUGAR Installation Instructions For best performance and continued durability, please take note of the following key points: 1. Use only premium grade fuel 92 octane or higher (R+M/2). 2. The engine must have stock compression ratio. 3. If the engine has been modified in any way, check with Vortech prior to using this product. 4. Always listen for any sign of detonation (pinging) and discontinue hard use (no boost) until problem is resolved. 5. Perform an oil and filter change upon completion of this installation and prior to test driving your vehicle. Thereafter, always use a high grade SF rated engine oil or a high quality synthetic, and change the oil and filter every 3,000 miles or less. Never attempt to extend the oil change interval beyond 3,000 miles, regardless of oil manufacturer’s claims as potential damage to the supercharger may result. 6. Before beginning installation, replace all spark plugs that are older than 1 year or 10,000 miles with original heat range plugs as specified by the manufacturer and reset timing to factory specifications (follow the procedures indicated within the factory repair manual and/or as indicated on the factory underhood emissions tag). Do not use platinum spark plugs unless they are original equipment. Change spark plugs at least every 20,000 miles and spark plug wires at least every 50,000 miles. TOOL & SUPPLY REQUIREMENTS: •Factory Repair Manual •3/8″ Socket and Drive Set: SAE & Metric •1/2″ Socket and Drive Set: SAE & Metric •3/8″ NPT Tap and Handle •Adjustable Wrench •Open End Wrenches: 3/8″, 7/16″, 1/2″, 9/16″ •Center Punch •Ford Springlock 3/8″ Fuel Fitting Disconnect Tool •5 Quarts SH/CF Rated Quality Engine Oil •Oil Filter and Wrench •Flat #2 Screwdriver •Phillips #2 Screwdriver •Heavy Grease •Silicone Sealer •Drill Motor •1/8″, 3/16″, 27/64″ Drill Bits •9/16″ Rota Broach Tool (also available from Vortech) •Molylube •Wire Strippers and Crimpers •Utility Knife If your vehicle has in excess of 10,000 miles since its last spark plug change, then you will also need: •Spark Plug Socket •NEW Spark Plugs

FORD, MERCURY, LINCOLN WHITE FLAKES COMING FROM A/ C VENTS SERVICE PROCEDURE

download
FORD: 2007-2009 MKX 2005-2009 Focus 2008-2010 Crown Victoria MERCURY: 2000-2005 Expedition, F-150 2008-2010 Grand Marquis, Mariner Hybrid, 2007-2009 Edge Mariner 2008-2010 Escape Hybrid, Escape LINCOLN: 2008-2010 Town Car SERVICE PROCEDURE MAY BE NECESSARY TO TEMPORARILY START THE ENGINE TO ENABLE MODE DOOR Hazard and Risk Warnings for White Flakes MOVEMENT. WARNING Clean A/C Ducts: MAY CAUSE EYE AND RESPIRATORY TRACT 1. Remove floor duct trim. IRRITATION. PROLONGED REPEATED EXPOSURE MAY CAUSE BONE DAMAGE 2. Using masking tape, connect one end of the (FLUOROSIS) AND HARM TO THE vacuum cleaner hose to the floor duct on driver RESPIRATORY SYSTEM (BASED ON ANIMAL side. DATA). • Avoid inhaling dust. 3. Tape closed all the other floor duct openings. • Avoid contact with eyes. 4. Obtain about two feet (61 cm) of rubber • Store away from acids. vacuum line large enough to fit the end of a small shop air blowgun. Secure the hose to the • Wash thoroughly after handling. end of the blowgun using a worm clamp. • Avoid release to the environment. 5. Close all instrument panel registers. NOTE THE USE OF DUST PROOF GOGGLES, 6. Set temperature setting to full cold. CHEMICAL RESISTANT GLOVES (PVC) AND 7. Place mode in floor / panel. DUST MASK IS RECOMMENDED. 8. Turn on vacuum cleaner

2002 Mercury Sable V6-3.0L VIN 2 Flex Fuel Repair Manual

download
Automatic Transmission/Transaxle Tune-Up B 0.0 1.5 Notes Includes: R&R Trans Pan, Service Filter And Make All Necessary Adjustments. Diagnose/Test AX4N/4F50N Oil Leak, Diagnosis B 0.0 0.5 Notes Includes: Clean And Dry Outside Of Case And Operating Unit To Determine Point Of Leakage. Transaxle, Diagnosis A 0.0 1.8 Notes Includes: Time To Hook-Up And Disconnect Test Equipment. Checking System For Fault Codes, Road Test And Hydraulic Pressure Test As Required. AXOD-E, AX4S Oil Leak, Diagnosis B 0.0 0.5 Notes Includes: Clean And Dry Outside Of Case And Operating Unit To Determine Point Of Leakage. Transaxle, Diagnosis A 0.0 1.8 Notes Includes: Time To Hook-Up And Disconnect Test Equipment. Checking System For Fault Codes, Road Test And Hydraulic Pressure Test As Required. Replace AX4N/4F50N Complete Assembly Without Transfer Of Parts B 5.0 7.3 Notes NOTE To R&R Driveplate, Add B 0.0 0.2 Notes To R&R Torque

2000 Audi A6 OIL PAN (A4 And A6) Removal And Installation Manual

download
OIL PAN(A4 & A6) Removal (Lower Pan- A4 & A6) 1. Disconnect negative battery cable. 2. Remove engine noise insulator (undercover). See Fig. 12 . Drain engine oil. 3. Unbolt left and right swaybar stabilizer bracket bolts (4) from mounting bracket. See Fig. 98 . Lower swaybar stabilizer not more than 10cm (3.94 INCHES) and secure with heavy wire. 4. If vehicle is equipped with automatic transmission, unbolt oil cooler pipe (line) bracket from right side oil pan. 5. Remove lower oil pan. To install oil pan (lower), see INSTALLATION (LOWER OIL PAN- A4 & A6) . Installation (Lower Oil Pan- A4 & A6) 1. Ensure oil pan surfaces are clean and dry. Remove residual sealant from oil pan, if necessary, with hand drill and plastic brush instead of a flat scrapper. See Fig. 99 . Install gasket. 2. Install 2 bolts diagonal to each other (to hold up pan). Install the rest of the bolts and hand tighten. 3. Starting at center and moving outward, tighten lower oil pan to upper oil pan bolts to 10 N.m (89 INCH lbs.). Tighten oil pan drain plug 30 N.m (22 ft. lbs.). Wait 30 minutes before filling with engine oil. Tighten all bolts to specification. See TORQUE SPECIFICATIONS . 4. To complete installation, reverse removal procedure. Fill and bleed cooling system. See COOLING SYSTEM BLEEDING . Removal (Upper Oil Pan- A4 & A6) 1. Disconnect negative battery cable. Remove oil dipstick. Unbolt oil dipstick tube at front of cylinder head. Remove oil dipstick tube. 2. Remove engine noise insulator (undercover). See Fig. 12 . Drain engine oil. 3. Move lock carrier into service position. See LOCK CARRIER . This will allow servicing of front engine components and facilitate removal of oil pan. 4. Open coolant expansion tank cap, drain cooling system at radiator. Open the coolant pump bearing housing drain plug. Located at bottom of block near transmission bell housing, drivers side of vehicle. See Fig. 32 – Fig. 33 . If vehicle is equipped with automatic transmission, unbolt oil cooler pipe (line) CAUTION: Wear eye protection NOTE: Obtain radio code before disconnecting battery. For help in identifying components and component locations, refer to illustrations Fig. 108 -Fig. 109 . NOTE: If engine is out of car, ensure oil pan is aligned with cylinder block on flywheel side. 2000 Audi A6 1998-02 ENGINES’ ’2.8L V6 30-Valve 2000 Audi A6 1998-02 ENGINES’ ’2.8L V6 30-Valve bracket from right side oil pan. 5. Position Engine Support (10-222A) with (10-222A/3) engine support adapter, or equivalent, on bolted flanges of fenders. Connect support bracket to front and rear engine lifting eyes. Lift up engine as far as possible. DO NOT use excessive force to raise engine. 6. Cut tie wraps and open bracket supporting starter wiring. See Fig. 97 . Disconnect electrical connection at starter.

1999 Mercury Sable V6-3.0L DOHC A/ T-Cooler Flushing Service Manual

download
SERVICE PROCEDURE Prior methods of cooler flushing have not obtained the level of cooler cleaning and contaminant removal that is required to prevent repeat repairs. The “Turbo-Tank Heated Cooler Line Flusher” uses heated Automatic Transmission Fluid ( ATF ) and a pulsating action to loosen system contamination. Previous equipment used solvents to clean & flush coolers, lines and torque- converters. There are 2 issues with this method: Aerosol Solvents should never be used for several reasons. NOTE YOU MUST IDENTIFY THE RETURN COOLER LINE TO START THE BACK FLUSHING PROCEDURE. A quick way to identify the return cooler line (fluid coming out of the cooler and returning to the transmission) is to locate the return cooler line fitting on the transmission case . Refer to the following lists: Rear Wheel Drive ^Residual solvent contamination can cause damage to friction bonding materials within the transmission (Clutches and Bands). ^Lack of fluid heating and agitation prevents this method from completely removing contamination from lines, in-radiator coolers and auxiliary coolers. ^They do not provide the volume necessary to remove heavy contaminants. ^They evaporate quickly and essentially leave contaminants in pockets, bends, or wherever they are as the solvent dries. ^TORQSHIFT, 4R100, E40D, C6 – The REAR transmission case filling receives the return line. ^4R70W, AODE, AOD – The TOP transmission case filling receives the return line. ^A4LD, 4R44/55E, 5R55E, 5R55N, 5R55W, 5R55S The TOP transmission case filling receives the return line. ^CD4E – The REAR or Pump End transaxle case fitting receives the return line. ^4F27E – The REAR or Cover End transaxle case fitting receives the return line. ^AXOD, AXODE, AX4S, AX4N, 4F50N – The BOTTOM transaxle cooler line fitting receives the return line. 1. Check and top off fluid level of the “Turbo-Tank Heated Cooler Line Flusher” tank with transmission fluid. 2. Allow the fluid in the flusher 15-30 minutes to heat up to 140°F (60°C) before using. 3. Install line adapters into the transmission cooler lines. 4. Attach the flusher’s blue line to the transmission return cooler line quick disconnect. 5. Attach the flusher’s red line to the transmission outlet cooler line quick disconnect. a. Follow equipment instructions, to purge cooler lines and cooler prior to starting flushing procedure (using factory installed purge valve and clear hose on “Turbo-Tank Heated Cooler Line Flusher”). 6. Allow the cooling system to back-flush for 10-15 minutes, then flush the cooler in a forward/normal flow direction for an additional 10-15 minutes