2001 Dodge Durango BLOWER MOTOR RELAYS REPAIR MANUAL

download
BLOWER MOTOR RESISTOR 1. Disconnect negative battery cable. Disconnect blower motor resistor harness connector. Using DVOM, check for continuity between all blower motor resistor terminals. If continuity exists between all terminals, go to next step. If continuity does not exist between all terminals, replace faulty blower motor resistor. 2. Check for open or short in circuits between blower motor resistor and heater control panel. Also check for open or short in wire between blower motor resistor and blower motor. BLOWER MOTOR SWITCH 2000 Dakota, 2000 Durango & 2000-01 Ram Pickup 1. Remove Power Distribution Center (PDC) cover. Using DVOM, check for battery voltage at PDC fuse No. 5 (40-amp) on Dakota and Durango; PDC fuse No. 12 (40-amp) on Ram Pickup. If battery voltage exists, go to next step. If battery voltage does not exist, check for open in Red wire between battery and underhood PDC. If Red wire is okay, replace underhood PDC. 2. Disconnect negative battery cable. Remove heater control panel. See HEATER CONTROL PANEL under REMOVAL & INSTALLATION. Disconnect heater control panel cable, electrical and vacuum connectors as necessary. Using DVOM, check for continuity between heater control panel harness connector terminal No. 7 (Black wire on Dakota and Durango; Black/Orange on Ram Pickup) and ground. See Fig. 5 . If continuity exists, go to step 4 . 3. If continuity does not exist, repair open in Black wire or Black/Orange wire between heater control panel 2001 Dodge Durango 2000-01 HEATER SYSTEMS’ ‘RWD Trucks & Vans harness connector terminal No. 7 and ground connector located at lower right corner of instrument panel (Dakota and Durango) or behind center of instrument panel (Ram Pickup). 4. Place heater mode control knob to any position except OFF. Using DVOM, check for continuity between heater control panel terminal No. 7 and terminals No. 3, 4, 5 and 6 while rotating blower motor switch. See Fig. 5 . 5. If continuity does not exist at any terminal, replace faulty heater control panel. If continuity exists as specified, check for open in circuits between heater control panel and blower motor resistor. Also check for an open in circuit between heater control panel and blower motor. See WIRING DIAGRAMS . Fig. 5: Identifying Heater Control Panel Blower Switch Connector Terminals (2000 Dakota & Durango Are Shown; Ram Pickup Is Similar) Courtesy of CHRYSLER CORP. Ram Van/Wagon 1. Disconnect negative battery cable. Remove heater control panel. See HEATER CONTROL PANEL under REMOVAL & INSTALLATION. Disconnect heater control panel harness connectors. Using DVOM, check for continuity between heater control panel C3 harness connector terminal “C” (Black wire) and ground. See Fig. 6 . If continuity exists, go to next step. If continuity does not exist, repair open in Black wire between heater control panel and ground connector located at lower right of steering column. 2. Place heater mode control selector to any position, except OFF. Using DVOM, check for continuity between appropriate terminals of heater control panel, for C3 connector terminals “B” (Violet wire) and “C” (Black wire). If continuity exists through heater control panel, go to next step. If continuity does not exist, replace faulty heater control panel assembly. 3. Using DVOM, check for continuity between heater control panel C3 connector terminal “B” (Violet wire) and C1 connector terminal “E” (Violet wire). See Fig. 6 . If continuity exists, go to next step. If continuity does not exist, repair open in Violet wire between heater control panel C3 and C1 connectors.

2000 Dodge Dakota & Durango Power Windows ADJUSTMENTS

download
ADJUSTMENTS WINDOWS Remove door trim panel. See DOOR TRIM PANEL under REMOVAL & INSTALLATION. Loosen bolts holding window to regulator. Raise window fully, seating window in frame. Tighten bolts. Install door trim panel. TROUBLE SHOOTING POWER WINDOWS On Dakota, inspect circuit breaker No. 20 (20-amp) in junction block. On Durango inspect circuit breaker No. 21 (25-amp) in junction block. On all models, junction block is located on left end of instrument panel. Inspect fuse No. 9 (40-amp on Dakota, 50-amp on Durango) in Power Distribution Center (PDC). PDC is located in left front corner of engine compartment. Inspect power window system ground circuit. See WIRING DIAGRAMS . SYSTEM TESTS ALL WINDOWS INOPERATIVE Dakota 1. Check circuit breaker for power window system. See TROUBLE SHOOTING . Replace circuit breaker as necessary. If circuit breaker is okay, go to next step. 2. Disconnect negative battery cable. Remove driver’s front power window switch. See POWER WINDOW SWITCH under REMOVAL & INSTALLATION. Check for continuity between ground and terminal No. 3 (Black wire) at driver power window switch wiring harness connector. If continuity exists, go to next step. If continuity does not exist, repair open in Black wire between driver power window 2000 Dodge Durango 2000 ACCESSORIES & EQUIPMENT’ ‘Power Windows – Dakota & Durango 2000 Dodge Durango 2000 ACCESSORIES & EQUIPMENT’ ‘Power Windows – Dakota & Durango switch connector and ground. See WIRING DIAGRAMS . 3. Connect negative battery cable. Turn ignition on. Measure voltage between ground and terminal No. 5 (Tan wire) at driver’s power window switch wiring harness connector. If battery voltage is present, check driver power window switch. See POWER WINDOW SWITCH under COMPONENT TESTS. If battery voltage is not present, repair open Tan wire between driver power window switch connector and ignition switch. See WIRING DIAGRAMS . See POWER DISTRIBUTION article in WIRING DIAGRAMS. Durango 1. Check circuit breaker for power window system. See TROUBLE SHOOTING . Replace circuit breaker as necessary. If circuit breaker is okay, go to next step. 2. Disconnect negative battery cable. Remove driver’s front power window switch. See POWER WINDOW SWITCH under REMOVAL & INSTALLATION. 3. Check for continuity between ground and terminal No. 5 (Black wire) at driver’s power window switch wiring harness connector. If continuity exists, go to next step. If continuity does not exist, repair open in Black wire between driver’s power window switch connector and ground. See WIRING DIAGRAMS . 4. Reconnect negative battery cable. Turn ignition on. Measure voltage between ground and terminal No. 4 (Tan wire) at driver’s power window switch wiring harness connector. If battery voltage is present, check driver’s power window switch. See POWER WINDOW SWITCH under COMPONENT TESTS. If battery voltage is not present, repair open Tan wire between driver power window switch connector and ignition switch. See WIRING DIAGRAMS . See POWER DISTRIBUTION article in WIRING DIAGRAMS. ONE WINDOW INOPERATIVE

2001-2004 FORD Taurus WATER IN THE BLOWER CASE—BLOWER MOTOR SERVICE PROCEDURE

download
SERVICE PROCEDURE 1. Access blower motor and resistor per the Workshop Manual Sections 412-02 and 412-04. Inspect for evidence of water/corrosion. If water/corrosion are found or parts have failed, replace per Workshop Manual (blower motor 1F1Z-19805-AA and resistor F6DZ-19A706-AA). 2. Visually inspect the Cowl Vent Screen located under the RH windshield wiper to verify if the Figure 1 – Article 04-15-3 screen is fully seated. Inspect the rubber seal on the vent screen which should be fully seated 5. Locate the tape as shown (Figure 2). Remove against the windshield. If the cowl vent screen the tape and apply Clear Silicone Rubber is not fully seated and appears warped, it must TA-32 to the small hole as shown (Figure 2). be replaced (4F1Z-54018A16-BAA) 3. Remove the cowl vent screen per the vehicle model years and build date information. Workshop Manual Section 412-01 Pollen Filter Removal and inspect the cabin filter to confirm ISSUE it is fully seated. Re-seat the filter as Some vehicles built between 5/1/2001 and necessary. Inspect rain-hat base to make sure 12/15/2003 may exhibit water in the blower case or it is secure and sealed to the body. Reposition on the passenger side floor, an inoperative climate and reseal as necessary using Clear Silicone control blower motor, a motor that operates on high Rubber TA-32. speed only, and/or a blower motor resistor failure. 4. Remove the foam sealant expulsion at lower front outboard corner base of the rain-hat ACTION (Figure 1). Inspect and seal cowl area and install Rain-Hat Extension Seal. Inspect and replace blower motor and/or blower motor resistor if there is evidence of water/corrosion. Refer to the following Service Procedure for details.

2000-2006 TOYOTA TUNDRA VEHICLE WIRING INFORMATION

download
WIRING INFORMATION: 2000 Toyota Tundra WIRE WIRE COLOR WIRE LOCATION 12V CONSTANT WIRE WHITE/RED OR WHITE Ignition Harness STARTER WIRE GREEN/BLACK Ignition Harness IGNITION WIRE BLACK/YELLOW Ignition Harness SECOND IGNITION WIRE BLACK/RED Ignition Harness ACCESSORY WIRE BLUE/RED Ignition Harness POWER DOOR LOCK (-) WHITE/GREEN Wires Can Be Found In A Harness In Both The Driver’s Kick Panel And In The Passenger Kick Panel POWER DOOR UNLOCK (-) RED/YELLOW Wires Can Be Found In A Harness In Both The Driver’s Kick Panel And In The Passenger Kick Panel PARKING LIGHTS (+) GREEN Harness In Drivers Kick Panel HEADLIGHTS (-) GREEN/YELLOW Harness At Steering Column DOOR TRIGGER (-) WHITE/BLUE Harness Coming Into Vehicle From Drivers Door DOME LIGHT SUPERVISION USE DOOR TRIGGER FACTORY ALARM ARM ARMS WITH LOCK FACTORY ALARM DISARM (-) BLUE/BLACK Drivers Door Harness TACHOMETER WIRE BLACK OR BLUE/WHITE Behind Instrument Cluster BRAKE WIRE (+) GREEN/WHITE Harness In Driver’s Kick Panel Or Brake Switch HORN TRIGGER (-) GREEN/RED Harness At Steering Column LEFT FRONT WINDOW UP GREEN At Driver Window Motor Inside Door LEFT FRONT WINDOW DOWN BLUE/YELLOW At Driver Window Motor Inside Door RIGHT FRONT WINDOW UP RED/BLACK Harness In Driver’s Kick From Driver Door RIGHT FRONT WINDOW DOWN RED/GREEN Harness In Driver’s Kick From Driver Door WIRING INFORMATION: 2001 Toyota Tundra WIRE WIRE COLOR WIRE LOCATION 12V CONSTANT WIRE WHITE/RED OR WHITE Ignition Harness STARTER WIRE GREEN/BLACK Ignition Harness IGNITION WIRE BLACK/YELLOW Ignition Harness SECOND IGNITION WIRE BLACK/RED Ignition Harness ACCESSORY WIRE BLUE/RED Ignition Harness POWER DOOR LOCK (-) WHITE/GREEN Wires Can Be Found In A Harness In Both The Driver’s Kick Panel And In The Passenger Kick Panel POWER DOOR UNLOCK (-) RED/YELLOW Wires Can Be Found In A Harness In Both The Driver’s Kick Panel And In The Passenger Kick Panel PARKING LIGHTS (+) GREEN Harness In Drivers Kick Panel HEADLIGHTS (-) GREEN/YELLOW Harness At Steering Column DOOR TRIGGER (-) WHITE/BLUE Harness Coming Into Vehicle From Drivers Door DOME LIGHT SUPERVISION USE DOOR TRIGGER FACTORY ALARM ARM ARMS WITH LOCK FACTORY ALARM DISARM (-) BLUE/BLACK Drivers Door Harness TACHOMETER WIRE BLACK OR BLUE/WHITE Behind Instrument Cluster BRAKE WIRE (+) GREEN/WHITE Harness In Driver’s Kick Panel Or Brake Switch HORN TRIGGER (-) GREEN/RED Harness At Steering Column LEFT FRONT WINDOW UP GREEN At Driver Window Motor Inside Door LEFT FRONT WINDOW DOWN BLUE/YELLOW At Driver Window Motor Inside Door RIGHT FRONT WINDOW UP RED/BLACK Harness In Driver’s Kick From Driver Door RIGHT FRONT WINDOW DOWN RED/GREEN Harness In Driver’s Kick From Driver Door LEFT FRONT WINDOW UP GREEN At Driver Window Motor Inside Door LEFT FRONT WINDOW DOWN BLUE/YELLOW At Driver Window Motor Inside Door RIGHT FRONT WINDOW UP RED/BLACK Harness In Driver’s Kick From Driver Door RIGHT FRONT WINDOW DOWN RED/GREEN Harness In Driver’s Kick From Driver Doo

2004 Pontiac Grand Prix Blower Motor Inoperative or Intermittent, Blower Speed May Drop or Blower Continues to Run After Key Off (Install a Capacitor at Blower Motor Control Module Connector) Service Manual

download
Technicians are to install a capacitor, P/N 25073556, at the blower motor control module connector using the following procedure: 1. Disconnect the negative cable from the battery. Refer to the Battery Negative Cable Disconnect/Connect procedure in the Engine Electrical section of SI. 2. Remove the right closeout/insulator panel. Refer to the Closeout/Insulator Panel Replacement-Right procedure in the Instrument Panel, Gages and Console section of SI 3. Disconnect the wire harness connector to the blower motor control module. 4. Install a capacitor, P/N 25073556, into the blower motor control module connector using the following steps. Refer to the illustration above to locate the positive and negative leads of the capacitor. Refer to the Splicing Copper Wire Using Splice Clips procedure in the Wiring Systems section of SI (Document ID #303646) for more information on using splice clips. 5. If the customer concern was of a blower motor that continues to run after key off, then replace the blower motor control module and install the capacitor . Refer to the blower motor control module Replacement procedure in the HVAC section of SI. This condition is the only time you need to replace the blower motor control module. 6. Reconnect the blower motor control module connector. 7. Install the right closeout/insulator panel. Refer to the Closeout/Insulator Panel Replacement- Right procedure in the Instrument Panel, Gages and Console section of SI. 8. Reconnect the negative cable to the battery. Refer to the Battery Negative Cable Disconnect/Connect procedure in the Engine Electrical section of SI. 9. Verify proper operation of the blower motor.