Komatsu WA900-3E0 Wheel Loader Shop Manual SEN05654-01

$50.00

  • Type Of Manual: Shop Manual
  • Manual ID: SEN05654-01
  • Format: PDF
  • Size: 3.5MB
  • Number of Pages: 173

Description

  • Model List:

    • WA900-3E0 Wheel Loader
  • 1. COVER
  • 2. Notice of revision
  • 3. Index and foreword
  • 3.1. Table of Contents
  • 3.1.1. Table of Contents
  • 3.2. Foreword
  • 3.2.1. Before reading this manual
  • 4. Specification
  • 4.1. Specification
  • 4.1.1. Specification dimension drawing
  • 4.1.2. Specifications
  • 4.1.3. Weight table
  • 4.1.4. Table of fuel, coolant and lubricants
  • 5. Structure and function
  • 5.1. Cooling system and related devices
  • 5.1.1. Cooling system
  • 5.2. Hydraulic system
  • 5.2.1. Power ladder system
  • 5.3. Electrical system
  • 5.3.1. Power ladder controller
  • 5.3.2. Rear view monitor system
  • 5.3.3. Engine service monitor system
  • 5.3.4. Parking brake circuit
  • 5.3.5. Sensor
  • 6. Standard value table
  • 6.1. Standard value table
  • 6.1.1. Standard value table for chassis
  • 6.1.2. Standard value table for electrical system
  • 7. Testing and adjusting
  • 7.1. Testing and adjusting
  • 7.1.1. Inspection and adjustment of potentiometer
  • 7.1.2. Ladder position calibration procedure
  • 7.1.3. Procedure for testing diodes
  • 8. Troubleshooting
  • 8.1. General information on troubleshooting
  • 8.1.1. Classification and procedures of troubleshooting
  • 8.1.2. Failure codes table
  • 8.1.3. Fuse locations
  • 8.2. Troubleshooting by failure code
  • 8.2.1. Failure code D1EMKA (Disconnection of parking brake interlock relay)
  • 8.2.2. Failure code D1EMKB (Ground fault of parking brake interlock relay)
  • 8.2.3. Failure code D1EMKY (Hot short of parking brake interlock relay)
  • 8.2.4. Failure code D1EPKA (Disconnection of ladder drive pump relay)
  • 8.2.5. Failure code D1EPKB (Ground fault of ladder drive pump relay)
  • 8.2.6. Failure code D1EPKY (Short circuit of ladder drive pump relay)
  • 8.2.7. Failure code D1EQKY (Ladder operation alarm relay output hot short circuit)
  • 8.2.8. Failure code D1EQKZ (Ladder operation alarm relay output abnormalityOpen circuit, ground fault)
  • 8.2.9. Failure code D1ERKB (Ladder raise solenoid output ground fault)
  • 8.2.10. Failure code D1ERKZ (Ladder raise solenoid output abnormality Open circuit, hot short circuit)
  • 8.2.11. Failure code D1ESKB (Ladder lower solenoid output ground fault)
  • 8.2.12. Failure code D1ESKZ (Ladder lower solenoid output abnormality Open circuit, hot short circuit)
  • 8.2.13. Failure code DBL0KR (Power ladder controller CANNET signal line open circuit)
  • 8.2.14. Failure code DBL0KT (Nonvolatile memory write error)
  • 8.2.15. Failure code DBL1KK (Power Low Error Battery direct)
  • 8.2.16. Failure code DBL2KK (Solenoid Power Low Error)
  • 8.2.17. Failure code DDB6KZ (Parking brake system abnormality)
  • 8.2.18. Failure code DDDGKY (Ladder operation switch hot short circuit)
  • 8.2.19. Failure code DDDKKY (Ladder raise operation switch hot short circuit)4035
  • 8.2.20. Failure code DDDLKY (Ladder lower operation switch hot short circuit)4038
  • 8.2.21. Failure code DK5VKX (Ladder angle sensor abnormality Out of range)
  • 8.2.22. Failure code DK5VMA (Power ladder system abnormality)
  • 8.2.23. Failure code DUM9KY (Ladder indicator output hot short circuit)
  • 8.2.24. Failure code DUM9KZ (Ladder indicator output abnormality Open circuit, hot short circuit)
  • 8.2.25. Failure code DV00KY (Ladder interlock caution output hot short circuit)
  • 8.2.26. Failure code DV00KZ (Ladder interlock caution output abnormality Open circuit, ground fault)
  • 8.2.27. Failure code DWNLKA (Ladder cushion valve output open circuit)
  • 8.2.28. Failure code DWNLKB (Ladder cushion valve output ground fault)
  • 8.2.29. Failure code DWNLKY (Ladder cushion valve output hot short circuit)
  • 8.3. Troubleshooting of electrical system (Emode)
  • 8.3.1. E1 Power ladder does not operate
  • 8.3.2. E2 Brake oil temperature warning keeps lighting
  • 8.3.3. E3 Parking brake does not operate (as emergency brake)
  • 8.3.4. E4 Parking brake is applied while machine is traveling.
  • 8.3.5. E5 Parking brake is released as starting switch is turned to ON position.
  • 8.4. Troubleshooting of hydraulic and mechanical system (Hmode)
  • 8.4.1. H1 Power ladder does not move or its speed is low
  • 8.4.2. H2 Fan of ADD cooler does not rotate
  • 8.5. Troubleshooting of maintenance monitor system (K mode)
  • 8.5.1. Maintenance monitor system
  • 8.5.2. K1 Hydraulic oil level gauge flashes
  • 8.6. Troubleshooting for machine monitor (Mmode)
  • 8.6.1. M1 Rear view monitor does not operate
  • 8.6.2. M2 While clearance lamp is turned on, illuminance of rear view monitor remains dark
  • 8.6.3. M3 Rear view monitor does not work in reverseinterlock mode
  • 8.6.4. M4 Illuminance of rear view monitor cannot be adjusted
  • 8.6.5. M5 Optional controller error and realtime monitor sreen are not displayed on engine service monitor
  • 8.6.6. M6 Engine compartment lamp does not light up
  • 8.6.7. M7 Step lamp does not light up
  • 9. Diagrams and drawings
  • 9.1. Hydraulic circuit diagram
  • 9.1.1. Symbols used in hydraulic circuit diagram
  • 9.1.2. Power train hydraulic circuit diagram
  • 9.1.3. Brake, power ladder and additional cooler Hydraulic circuit diagram
  • 9.1.4. Work equipment hydraulic circuit diagram
  • 9.2. Electrical circuit diagram
  • 9.2.1. Symbols used in electric circuit diagram
  • 9.2.2. Electrical circuit diagram
  • 9.2.3. Connector arrangement diagram
Rate this product
Reviews

There are no reviews yet.

Be the first to review “Komatsu WA900-3E0 Wheel Loader Shop Manual SEN05654-01”

Your email address will not be published. Required fields are marked *